HOME / TECHNICAL CENTRE
Five inputs needed to design a GRP/GRE system
Fluid, temperatures, pressures including surges, routing and project requirements. DN and PN are not enough. Learn why and what to send before finalising the specification.
Choose a topic below: materials, operating conditions, joints or repairs.
CHECKLIST / DESIGN INPUTS
Five inputs needed for design and pricing.
DN and PN appear in almost every enquiry. Without the information below, you may be comparing unlike solutions.
01
Fluid
Composition, concentration, additives, particles and cleaning chemicals.
02
Temperatures
Operating, maximum and minimum temperatures, peaks and their duration.
03
Pressures
Operating, design and test pressures, including vacuum and pressure surges.
04
Routing
Installation, supports, valves, interfaces and external loads.
05
Requirements
Applicable standard, such as ISO 14692, service life, documentation and installer qualifications.
01 / START WITH YOUR TASK
Start with a checklist, not a catalogue.
System selection
Six conditions affecting chemical resistance. “Will it resist acid?” is not enough.
Explore the topic ↗Project considerations
How to describe the requirements so that connections to existing equipment can be assessed.
Explore the topic ↗Joints and quality
One joint can make the difference. Steel experience alone is not enough.
Explore the topic ↗Operation and repairs
Repeated chemical attack calls for investigating the cause. Check the specification before replacing the pipe.
Explore the topic ↗02 / TECHNICAL KNOWLEDGE MAP
From selection to installer training. Seven areas that matter in a project.
Practical guidance on chemical resistance, pressure surges, joints and specifications. Decision support, not a product catalogue.
01
Materials and selection
GRP and GRE, resins and inner layers. A composite is not simply lighter steel.
02
Project considerations
Five design inputs. DN and PN are not enough.
03
Joining technologies
Adhesive-bonded, laminated and flanged joints. Each has its own procedure.
04
Preparation and installation
Supports, expansion and valves. Do not adopt a steel layout unchanged.
05
Quality and verification
Joint records, batches and inspection. Acceptance requirements are defined before installation.
06
Operation and repairs
Chemical attack, abrasion and pressure surges. PN alone is not enough.
07
Training and collaboration
Training for a specific joining technology. Skills assessment, not independent certification.
03 / SELECTED QUESTIONS
Questions to ask before placing an order.
SELECTION
GRP or GRE? Why the abbreviation is not enough.
Polyester, vinyl ester, epoxy. Limits apply to the system, not three letters.
Read the topic ↗JOINTS
One joint can affect the entire line.
Surface preparation, batches, curing and records. Steel experience alone is not enough.
Read the topic ↗QUALITY
Why does joint traceability matter?
How a joint label supports acceptance, claims and later repairs.
Read the topic ↗The specific design, procedure and documentation follow once we understand your requirements.
Discuss your project ↗Still have a question about your fluid or joint?
Describe the fluid, damage or joint. We will establish whether you need a consultation or a quotation.
Prepare for your consultation.
The checklist helps describe the fluid, process and scope. The blank joint record is a working template, not an installation procedure or approved inspection form.
Download the enquiry checklist (TXT) ↗Download a blank joint record (CSV) ↗RELATED TOPICS